SERVICES WE PROVIDE
Jacksonville Duval County 904-346-1266
St Augustine St Johns County 904-824-7144
Orange Park Clay County 904-264-6444
Jacksonville Beaches Duval County 904-246-3969
Fernandina Nassau County 904-277-3040
Macclenny Baker County 904-259-5091
Palm Coast Flagler County 386-439-5290
Daytona Volusia County 386-253-4911
Serving all of Florida and Georgia at 904-346-1266
EMAIL LARRY@1STPROP.COM (feel free to email your bidding packages here)
Residual fats, oils and grease (FOG) is a by-product from food service establishments. Typically, FOG enters a facility’s plumbing system from ware washing, floor cleaning, and equipment sanitation. Sanitary sewer systems are neither designed nor equipped to handle the FOG that can accumulate on the interior of the sewer collection system pipes from improperly maintained discharges. These accumulations may cause a sanitary sewer overflow (SSO). A SSO is the unintentional flow of untreated sewage onto the ground or into a facility, home, or waterway. SSOs create a health risk to the public, damage property, and pollute our environment.
Frequently Asked Questions
How to Properly Clean your Small Grease Trap (units under 50 gallons) Tool & Materials 1. A large trash can 2. 2 or 3 trash can liners/bags (thick or heavy duty) 3. Absorbent material (Floor dry available at auto parts store or clay kitty litter) 4. Proper hand tools and safety equipment to open trap
a. hex head wrench (allen wrench), screw driver/small pry bar, scraper, rubber gloves and safety glasses
5. Tools for removing contents
a. scoop of some type b. scraper (for cleaning the internal parts) c. wet/dry vacuum (optional)
6. Towels/rags Let’s begin: 1. Prepare your work area (clear area of debris, bleach bottles, and other cleaners). 2. Line the trash can with the garbage bags. 3. Add absorbent material (floor dry or kitty litter) into the lined trash can. This will soak up the water and liquid waste making transport of waste to the dumpster cleaner and safer. Dig in: 1. Remove the lid of the grease trap. 2. Observe the manner in which the internal parts are installed because you’ll have to re-install them properly when you finish cleaning the trap. 3. Begin removing contents of the grease trap by dipping or vacuuming the waste products from the inside of the grease trap 4. Remove all contents until grease trap is empty 5. Do NOT use hot water, degreasers, or soaps to clean the interior of the trap. 6. Scrape all the inside walls, baffles, and screens to insure movement of water through unit. 7. Inspect and note condition of tank, baffle and all removable parts. Schedule repairs or replacement as needed. 8. Make sure the grease trap has been properly reassembled (all internal parts are in their proper place). 9. Examine the gasket for damage. Replace if necessary – never use tube silicone as a gasket . 10. Clean and re-install rubber gasket and reposition lid on tank. Ensure all screws and holddowns are in place and properly tightened. 11. Ensure enough absorbent material has been placed in bag to soak up all excess liquids. Add more if needed. Securely tie the bag of waste closed so that it does not leak. 12. Place bag in the garbage (solid waste) dumpster or designated receptacle. It is illegal to dump grease trap or kitchen waste into storm drains, ponds or outdoor areas. Document and report your maintenance as required by Industrial Pretreatment Regulation: 1. Complete an entry on the small trap maintenance log to be kept onsite. 2. Complete an entry on the small trap pump-out report which should be mailed in monthly. Cleaning your Grease Trap frequently is “a good thing” for the following reasons: 1. Fewer smells and odors – The longer waste is trapped the stronger the odors it generates2. Longer trap life –
Rotting foods create acids which eat away at the internal components and tank.
Best management practices (BMP) are designed to help facilities comply with environmental regulations and prevent pollution. This BMP contains a set of operating procedures and guidelines designed to reduce the amount of fats, oils, and grease (FOG) discharged to the JEA Publicly Owned Treatment Works (POTW). The development of this BMP is intended to reduce the amount FOG introduced to the JEA sanitary sewer system and protect the public health and environment from the hazards presented by sanitary sewer overflows. As part of the Clean Water Act, the National Pretreatment Regulation (40CFR 403) was established to protect POTWs and the waterways in which they discharge. The Environmental Protection Agency (EPA) delegates this responsibility to the State of Florida Department of Environmental Protection (DEP). In Jacksonville, FL, the State has delegated local authority to JEA (an electric, water, and sewer utility). It is the responsibility of the JEA Industrial Pretreatment (IP) program to regulate non-residential discharges to the POTW. BMP guidelines are enforceable through the JEA Industrial Pretreatment Regulation. Through this regulation, food service establishments (FSEs) and commercial kitchens are required to follow the guidelines and operating procedures laid out in this document. If it is determined a FSE is not utilizing Best Management Practices, JEA may apply the Industrial Pretreatment Regulation as necessary to protect the JEA sanitary sewer system, the environment and public wellbeing.
Background
FSEs are commercial facilities that prepare and or serve food or beverages for sale or consumption. Through daily activities working with food, all FSEs generate varying amounts of FOG. While fats, oils, and grease are most commonly associated with fried foods, they are generated in significant quantities in all types of commercial food preparation:
• Cooking meats
• Mayonnaise and salad dressings
• Butter, ice cream and other dairy products
• Creams and sauces
Statement of Problem
FOG tends to coat any pots, pans, ware, utensils, and equipment in which it contacts. When these materials are washed, the FOG is rinsed to the sewer. Sanitary sewer systems are neither designed nor equipped to handle FOG. In the sewer, the FOG coats the interior surface of the pipes. Overtime, FOG accumulations restrict the flow of wastewater through the sewer. Eventually the FOG can clog the sewer pipes causing the sewage to back up and spill onto the ground, waterways, and homes or buildings. This is called a sanitary sewer overflow (SSO) and endangers both the public health and the environment. – 4 – Fats, oils, and grease can also cause interference at the wastewater treatment facility (WWTF). The FOG can negatively impact operations resulting in improper treatment of pollutants. These pollutants that are otherwise removed by the treatment process could be discharged to the river.
Policy
Discharges of fats, oils, and grease present a potential problem to the proper conveyance and treatment of sanitary sewage. JEA, as the control authority, is required to regulate discharges from food service establishments. It is the policy of the JEA Industrial Pretreatment program to require food service establishments discharging to the sanitary sewer system to abide by this policy and implement the best management practices in this document to minimize the amount of FOG entering the POTW. Statement of Discharge Policy 1. All discharges from FSEs must be in accordance with applicable state, local or federal rules and regulations. 2. All FSEs unless otherwise determined by JEA, must have a properly sized and operational grease interceptor (large external device) or grease trap (smaller “under the sink” fixture). 3. Sizing and design of grease traps and interceptors must meet the criteria set forth in the Florida Building Code, Chapter 10, Plumbing and be approved by the City of Jacksonville Building Inspection Devision. 4. All FOG bearing drains must be plumbed to the interceptor. 5. All grease interceptors and traps must be maintained on a regular basis.
Required Maintenance Practices
|